Tohodo Scientific Instrument - Jual Alat Pertanian dan Alat Perikanan
Verified Supplier
Tambah ke Favorit
sql

Portable Turbidimeter 2100Q (ALAT UKUR kEKERUHAN)

Rp. 123
Last Updated
21 Sep 2021
Minimum Order
1 Unit

Specification of Portable Turbidimeter 2100Q (ALAT UKUR kEKERUHAN)

Portable Turbidimeter 2100QSpecifications Accuracy:± 2 % of reading plus stray light of reading plus stray light Battery Requirements:4, AA Certification:CE/RoHS/WEEE Certifications:CE certified Data Logger:500 records Dimensions (H x W x D):3 in x 4.2 in x 9 in (77 mm x 107 mm x 229 mm) Display Size:240 x 160 pixels Enclosure Rating:IP67 Includes:Instrument, case assembly, 4 AA alkaline batteries, 6 sample cells, StablCal ampule kit, silicone oil, oiling cloth, manual. Interface:Optional USB Light Source:tungsten filament lamp Max. operating humidity:90 Measurement Method:Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal Measurement Modes:Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity Measuring Range:0 - 1000 NTU Operating Temperature Range:0 - 50 °C Path Length:25 mm N/A Power Requirements:100 - 240 VAC, 50/60 Hz (with optional Power or USB+Power module) Power Requirements (Hz):50/60 Hz Power Requirements (Voltage):100 - 240 V AC Power Supply:Batteries (see Battery Requirements) or Optional Power Supply Regulatory:EPA Method 180.1 Repeatability:± 1 % of reading or 0.01 NTU , whichever is greater Resolution:0.01 NTU on lowest range Response Time:6 s in normal reading mode Sample Cell Compatibility:25 mm x 60 mm round Sample Requirements:15 mL (0.5 oz) Signal Averaging:Selectable on/off Storage Conditions:-40 °C to 60 °C Unit:NTU User Interface Languages:English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish Weight:1.17 lbs. (0.53 kg) without batteriesIncluded: Portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, primary calibration standards in 1 sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and CD-ROM), quick start guide, silicone oil and oiling cloth.
Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1
Logo IDT
Chatbot